Vpacket Hotwire 5100 Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Vernetzung Vpacket Hotwire 5100 herunter. vpacket Hotwire 5100 User`s guide [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 59
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
AREA CODE CHANGE
Please note that the area code for
Paradyne Corporation in Largo, Florida
has changed from 813 to 727.
For any Paradyne telephone number that
appears in this manual with an 813 area
code, dial 727 instead.
Seitenansicht 0
1 2 3 4 5 6 ... 58 59

Inhaltsverzeichnis

Seite 1 - AREA CODE CHANGE

AREA CODE CHANGEPlease note that the area code forParadyne Corporation in Largo, Floridahas changed from 813 to 727.For any Paradyne telephone number

Seite 2 - CENTRAL OFFICE

1-15100-A2-GB20-00November 1996About HotWire DSL1What Is the HotWire 5100 DSL Access System?The HotWire DSL Access System provides high-speed Interne

Seite 3 - Printed on recycled paper

About HotWire DSL 1-25100-A2-GB20-00November 1996These specific management information bases (MIBs) are supported:— MIB II System and Interface Groups

Seite 4 - Important Safety Instructions

About HotWire DSL 1-35100-A2-GB20-00November 1996HotWire DSL RequirementsHardware RequirementsHotWire DSL requires an Intel 80486 or Pentium, NEBS-com

Seite 5 - Contents

2-15100-A2-GB20-00November 1996Installing and Connecting theCard2Package ContentsThe HotWire DSL CO product consists of:H CO DSL cardH HotWire DSL CO

Seite 6 - 5 Configuring the SNMP Agent

Installing and Connecting the Card 2-25100-A2-GB20-00November 1996In addition to Steps 1–9, a HotWire DSL CP card must be installed in acustomer’s PC

Seite 7

Installing and Connecting the Card 2-35100-A2-GB20-00November 1996Configuration Table for SW1 SwitchesCO PC SlotNumberChannelNumberI/O BaseAddressSwit

Seite 8 - About This Guide

Installing and Connecting the Card 2-45100-A2-GB20-00November 1996Setting IRQ Switches to OffIRQ (hardware interrupt request) DIP switch banks SW2 and

Seite 9 - Product-Related Documents

Installing and Connecting the Card 2-55100-A2-GB20-00November 1996Connecting the Card to the LAN Network and POTSNetworkThe figure below identifies th

Seite 10 - About HotWire DSL

Installing and Connecting the Card 2-65100-A2-GB20-00November 1996Connecting to the LAN NetworkProcedure1. Plug the end of an 8-pin modular cable int

Seite 11 - Operating Environment

Installing and Connecting the Card 2-75100-A2-GB20-00November 1996P2P3POTS Splitter RackMulti-pinBlock #1Connects toMulti-pinBlock #2496-15026

Seite 12 - HotWire DSL Requirements

HOTWIRE 5100 DSLACCESS SYSTEMCENTRAL OFFICEUSER’S GUIDEDocument No. 5100-A2-GB20-00November 1996

Seite 13 - Installing and Connecting the

Installing and Connecting the Card 2-85100-A2-GB20-00November 1996Four rows of pins of a multi-pin block are dedicated to each CO card/POTSsplitter pa

Seite 14 - Setting I/O Base Address

Installing and Connecting the Card 2-95100-A2-GB20-00November 1996Always connect the CO switch tip and ring leads to the bottom twoA-column pins of a

Seite 15

Installing and Connecting the Card 2-105100-A2-GB20-00November 1996Connecting to the POTS Network Using Standalone POTS SplittersProcedure1. Install

Seite 16 - Setting IRQ Switches to Off

Installing and Connecting the Card 2-115100-A2-GB20-00November 1996Installing the SoftwareThe HotWire DSL CO product software consists of three compon

Seite 17 -  J2 for POTS connection

Installing and Connecting the Card 2-125100-A2-GB20-00November 1996c:\Windows\system32\drivers\genport.sys (orc:\WinNT35\System32\drivers\genport.sys)

Seite 18 - Connecting to the LAN Network

3-15100-A2-GB20-00November 1996Accessing the CentralManagement Utility3OverviewThere are three ways to access the CO card in order to configure and m

Seite 19 - November 1996

Accessing the Central Management Utility 3-25100-A2-GB20-00November 1996Accessing the Central Management Utility Locally The procedure that follows de

Seite 20

Accessing the Central Management Utility 3-35100-A2-GB20-00November 19963. From the PC keyboard, type:cd c:\HOTWIREhotwire.exeAlternatively, follow th

Seite 21

Accessing the Central Management Utility 3-45100-A2-GB20-00November 1996Setting the Terminal Interface OptionsThe terminal interface options of the te

Seite 22 - Connecting to a Terminal

Accessing the Central Management Utility 3-55100-A2-GB20-00November 1996Automatically Running the Central ManagementUtilityThe following procedure des

Seite 23 - Installing the Software

Printed on recycled paper A5100-A2-GB20-00November 1996Copyright 1996 Paradyne Corporation.All rights reserved.Printed in U.S.A.NoticeThis publicati

Seite 24 - " Procedure

Accessing the Central Management Utility 3-65100-A2-GB20-00November 199613. Power down the CO PC.14. Disconnect the CO PC monitor and keyboard.15. Pow

Seite 25 - Management Utility

4-15100-A2-GB20-00November 1996Configuring and Managing theCard4OverviewThe Hotwire DSL Central Management Utility enables you to configure andmanage

Seite 26 - VT100-Compatible Terminal

Configuring and Managing the Card 4-25100-A2-GB20-00November 1996Menus That Require InputThe following menus require that you input information (other

Seite 27 -  Procedure

Configuring and Managing the Card 4-35100-A2-GB20-00November 1996(The Set Filters menu enables you to configure multiple MAC and IP filter sourceaddre

Seite 28

Configuring and Managing the Card 4-45100-A2-GB20-00November 1996Configuring and Managing the CardThe central management utility enables you to: Moni

Seite 29

Configuring and Managing the Card 4-55100-A2-GB20-00November 1996Operational Status Display (CO) (2 of 2)Parameter DescriptionMAC Broadcast PacketsRec

Seite 30

Configuring and Managing the Card 4-65100-A2-GB20-00November 1996Error Status (CO Cards)The Error Status screen displays the errors related to the ope

Seite 31 - Overview

Configuring and Managing the Card 4-75100-A2-GB20-00November 1996Error Status (CP Cards)The Error Status screen displays the errors related to the ope

Seite 32 - Menus That Require Input

Configuring and Managing the Card 4-85100-A2-GB20-00November 1996Board ID (CO and CP Cards)The Board ID screen shows identifying information about the

Seite 33 - Read-Only Menus

Configuring and Managing the Card 4-95100-A2-GB20-00November 1996Diagnostics Display (2 of 2)Parameter DescriptionLoopback Type Loopbacks available to

Seite 34

Important Regulatory Information B5100-A2-GB20-00 November 1996Important Safety Instructions1. Read and follow all warning notices and instructions ma

Seite 35

Configuring and Managing the Card 4-105100-A2-GB20-00November 1996Firmware UpgradeThe Firmware Installation screen enables you download code into the

Seite 36 - Set Filters

Configuring and Managing the Card 4-115100-A2-GB20-00November 1996Filters Display (2 of 2)Parameter DescriptionIP Filter Source Address Used to filter

Seite 37

Configuring and Managing the Card 4-125100-A2-GB20-00November 1996Configure DSL CardsThe Configure DSL Card screens enables you to set the data rate o

Seite 38 - Diagnostics

5-15100-A2-GB20-00November 1996Configuring the SNMP Agent5SNMP Interface ModelThe DSL modem SNMP management model is that of a single CO PC addressed

Seite 39 - Diagnostics

Configuring the SNMP Agent 5-25100-A2-GB20-00November 1996Configuration After installing the SNMP agent (as described in Chapter 2), you can configure

Seite 40

Configuring the SNMP Agent 5-35100-A2-GB20-00November 1996Up to four destination addresses may be entered. If no destination addresses areentered, no

Seite 41 - Parameter Description

6-15100-A2-GB20-00November 1996Diagnostics6OverviewHotWire DSL provides you with three ways to monitor the health and status of itscards and connecti

Seite 42 - Configure DSL Cards

Diagnostics 6-25100-A2-GB20-00November 1996LED StatusThere are 10 LEDs on the CO card.496-1498212345678123456781234TEST SYSTXRXCOLJABTXRXCDLNKEthernet

Seite 43 - Configuring the SNMP Agent

Diagnostics 6-35100-A2-GB20-00November 1996The following table describes the meaning and states of the LEDs.TypeLED LED is . . . Indicating . . .DSLLN

Seite 44 - Configuration

Diagnostics 6-45100-A2-GB20-00November 1996Using the Loopback TestsWhen you encounter a problem with a HotWire connection, try to determinewhether the

Seite 45 - PDU Trace

i5100-A2-GB20-00November 1996ContentsAbout This Guide Purpose and Audience v. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 46

Diagnostics 6-55100-A2-GB20-00November 1996LAN LoopbackThe LAN loopback enables data received from the CO card ISA bus to be loopedback by the Etherne

Seite 47 - LED Status

Diagnostics 6-65100-A2-GB20-00November 1996Remote LoopbackThe remote loopback enables data received from the CO ISA bus to be loopedback by the firmwa

Seite 48 - Using the Loopback Tests

A-15100-A2-GB20-00November 1996PinoutsAJ1 Ethernet Connector PinoutsPin Number Use1 TX Data +2 TX Data –3 RX Data +4 NC (unused)5 NC (unused)6 RX Dat

Seite 49

B-15100-A2-GB20-00November 1996Installing POTS Splitter atCustomer PremisesBHow to Install the POTS SplitterThe following procedure describes how to

Seite 50 - Local Loopback

Installing POTS Splitter at Customer Premises B-25100-A2-GB20-00November 1996Use the following procedure to wire the POTS splitter. Procedure1. Attac

Seite 51 - Remote Loopback

Installing POTS Splitter at Customer Premises B-35100-A2-GB20-00November 1996ToSubscriber LoopTo DSL Card inCustomer PCTelephone Network InterfacePOTS

Seite 52 - J1 Ethernet Connector Pinouts

C-15100-A2-GB20-00November 1996Technical SpecificationsCTechnical SpecificationsThe following table lists the technical specifications for the CO car

Seite 53

GL-15100-A2-GB20-00November 1996GlossaryAsymmetric high-bit-rate Digital Subscriber Loop. Provides high-speed digital rates to acustomer premises, whi

Seite 54

IN-15100-A2-GB20-00 November 1996IndexBboard idCO card, 4-8CP card, 4-8Ccentral management utilitymenus, 4-4operation, 3-1, 4-1configurationautom

Seite 55

IndexIN-25100-A2-GB20-00November 1996PPC configuration, 1-3POTS splittercentral office installation, 2-6customer premises installation, B-1part of

Seite 56 - Technical Specifications

Contents ii5100-A2-GB20-00November 19963 Accessing the Central Management Utility Overview 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 57 - Glossary

Contents iii5100-A2-GB20-00November 19966 Diagnostics Overview 6-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 58

v5100-A2-GB20-00November 1996About This GuidePurpose and AudienceThis guide describes how to install and configure the Central Office (CO)component o

Seite 59

Contents vi5100-A2-GB20-00November 1996Section DescriptionAppendix BInstalling POTS Splitter at Customer Premises.Describes how to install the POTS sp

Kommentare zu diesen Handbüchern

Keine Kommentare